Dental Anti-fog Mirrors with LED Light Automatic Oral Defog Orthodontic Mirror
1. INTRODUCTION
The Fog Free Photo generates the light and breeze, this can cause the reflector deforgging, and assist the dentist taking photos in the mouth.
Set for intraoral photography. It avoids fogging of the mirror and also gives extra light to the oral cavity.
The kit has 4 types of mirrors. 100% reflectivity. The main function of the device is to assist in oral photography. Automatic defogging, large viewing angle and easy operation. Stainless steel mirror can be autoclaved.
At the time of purchase, you can choose a complete set of 4 mirrors. Or buy mirrors separately
_____________________________________________
2.PRODUCT FEATURES:
1) Color: white
2) Specifications: 12x6.6x2cm
3) Anti-fog effect
4) Equipped with high-quality LED shadowless lamp
5) Intelligent double switch control
6) The device is equipped with four high quality stainless steel mirrors to meet the photographic requirements of
the maxillofacial and buccal surfaces
7) Built-in high-end current-limiting chip, automatic input current regulation, safety
protection
8) The handshake position is equipped with a smooth design pad to make your touch more comfortable.
_____________________________________________
3. TECHNICAL PARAMETERS
Battery: 1000mAh/3.7V
Input: 5V1A
Output: 1.8W Max
_____________________________________________
4. COMPLETE SET PACKING LIST:
Handle *1
Stainless steel mirror *4
USB charging cable *1
Cleaning cloth *1
(You can also choose mirrors individually)
_____________________________________________
5. CHARGING
1) When the light flashes, lightness is not enough or fan shutdown automatic, please stop using the device and recharge the battery.
2) Connect the AC adapter with the bottom socket of the device properly, and insert the AC USB adapter plug to the power socket.
3) The red indicator is lighted when the device is charging, it means charging has finished when the red indictor turns green.
3)Insert the mirror to the back socket of the main unit, push the fan button and breeze the mirror, the mirror defogging, if the lightness is not enough.
4)The device will shutdown automatically after
3 minutes without oeration.
5)Pull the mirror out the main unit, disinfect and clean the device according to the user manual.
_____________________________________________
6. DISINFECTION, CLEANINGAND STERILIZATION
1) The main unit and the mirror must be cleaned, disinfected and sterilized before each use to prevent any contamination. This concerns the first use as well as the subsequent uses.
2) After each use, all the objects that were in contact
with infectious agents should be cleaned using towelsimpregnatedwithadisinfectingand detergentsolution(a bactericidal fungicidal and aldehyde free solution). Useofchemicalagents may cause damage to the equipment.
3)The mirror must be sterilized between treatments by autoclave 134℃
4) The main unit cannot be autoclaved.